Note: Code 93 must be enabled to use this example.
A - Code 39
B - Code 128
C - Code 93
You would set up the sequence editor with the following command line:
SEQBLK62999941FF6A999942FF69999943FF
The breakdown of the command line is shown below:
SEQBLKsequence editor start command 62 code identifier for Code 39
9999 code length that must match for Code 39, 9999 = all lengths
41start character match for Code 39, 41h = “A” FF termination string for first code
6A code identifier for Code 128
9999 code length that must match for Code 128, 9999 = all lengths
42start character match for Code 128, 42h = “B”
FFtermination string for second code
69 code identifier for Code 93
9999 code length that must match for Code 93, 9999 = all lengths 43 start character match for Code 93, 43h = “C”
FF termination string for third code
2 - 44