Hearth and Home Technologies 8300 owner manual Venting Configurations

Models: 8300

1 43
Download 43 pages 47.08 Kb
Page 21
Image 21

HearthStone Quality Home Heating Products Inc

Champlain Model #8300

VENTING CONFIGURATIONS

-2’ minimum system height (with or without offsets)

-30’ maximum system height (with or without offsets – note shutter setting)

-10’ maximum offset (refer to Figures 8, 9, & 11 – note shutter setting)

-maximum rise to run = 1 to 5 (refer to Figures 8 & 9 – note shutter setting)

-The termination must fall within the area outlined by the shaded area shown in Figure 8 and the Chart in Figure 9 should be considered as well.

Figure 11: Vertical Termination

APPROVED VERTICAL TERMINATION VENTING CONFIGURATIONS WITH:

1.

Two 90º Elbows

2.

Two 45º Elbows

3.

No Elbows

90º Elbow

45º Elbow

Straight Pipe

Straight Pipe

Straight Pipe

 

 

21

Page 21
Image 21
Hearth and Home Technologies 8300 owner manual Approved Vertical Termination Venting Configurations with