HearthStone Quality Home Heating Products Inc

Champlain Model #8300

HORIZONTAL TERMINATION VENTING CONFIGURATIONS

-A minimum of 2’ rise is required (with or without offsets)

-30’ maximum system height (with or without offsets – note shutter setting)

-10’ maximum offset (refer to Figures 8, 9, & 12 – note shutter setting)

-maximum rise to run = 1 to 5 (refer to Figures 8 & 9 – note shutter setting)

-The termination must fall within the area outlined by the shaded area shown in Figure 8 and the Chart in Figure 9 should be considered as well.

-Use a vinyl siding stand off when installing against a vinyl siding.

-Horizontal sections require a ¼” rise every 12” of horizontal run.

-For each 90º elbow after the second, remove 5’ from horizontal run.

-At minimum vertical rise, maximum horizontal run is 10’

-Use with snorkel termination 10’ maximum horizontal run.

Approved DV Venting Configuration for

Horizontal Termination with:

1. (1) 90º Elbow & (1) 45º Elbow

∙ 90º Elbow

∙ 45º Elbow

∙ Straight Pipe

2. (1) 90º Elbow

∙ 90º Elbow

∙ Straight Pipe

3. (2) 90º Elbow

∙ (2) 90º Elbows

∙ Straight Pipe

4. Snorkel

∙ Snorkel (3 foot) ∙ Straight Pipe

Figure 12. Horizontal Termination

22

Page 22
Image 22
Hearth and Home Technologies 8300 owner manual Horizontal Termination Venting Configurations