HearthStone Quality Home Heating Products Inc

Champlain Model #8300

FIREPLACE VENTING CONFIGURATIONS

30’ maximum system height (with or without offsets-note shutter setting)

10’ maximum offset (refer to Figures 8 – 10 shutter setting)

maximum rise to run = 1 to 5 (refer to Figures 8 – 10 note shutter setting)

termination must fall within the area outlined by the shaded area shown in Figure 8 and the chart in Figure 9 should be considered as well.

DV CLASS A CHIMNEY SYSTEMS (4)

-Chimney Conversion Kit A

-Chimney Conversion Kit B

-Chimney Conversion Kit C

-Masonry Chimney Conversion Kit

Co-Linear Flex Liner (10ft min/30ft max)

Co-Linear Flex Connector

High Wind Termination Cap

DV CHIMNEY CO-LINER SYSTEM

Chimney Liner Termination Kit (includes Co-Liner to Co-Axial Termination and Flashing)

(2) Sections 3” Flex Liners (10ft min/30ft max)

High Wind Termination Cap

Co-Axial to Co-Linear Appliance Connector

(4) 3-1/2” Hose Clamps

DV CHIMNEY CO-AXIAL LINER SYSTEM

Chimney Liner Termination Kit (includes Co-Linear to Co-Axial Termination and Flashing

(2)Sections 3” Flex Liners (10ft min/30ft max)

High Wind Termination Cap

Co-Axial to Co-Linear Appliance Connector

(4) 3-1/2” Hose Clamps

The use of an existing chimney as an air intake is not covered under the ANSI Z21.88-CSA 2.33-M98 test methods and the resulting ITS/WHI product certification. The Authority having jurisdiction must be consulted prior to proceeding with these installation methods.