2. Continue Adding Vent Components

To continue adding vent components in accordance with the pre-planned vent system configuration:

Ensure that each succeeding vent component is securely fitted and locked into the preceding com- ponent in the vent system.

90° elbows may be installed and rotated to any point around the preceding component’s vertical axis. If an elbow does not end up in a locked position with the preceding component, attach with a minimum of two

(2) sheet metal screws.

Continue adding vent components, locking each succeeding component into place.

Figure 10. Adding Venting Components

3. Install Support Brackets

For Horizontal Runs - The vent system must be supported every five (5) feet of horizontal run by a horizontal pipe support.

To install support brackets for horizontal runs:

Place the pipe supports around the vent pipe.

Nail the pipe supports to the framing members.

18

Heat & Glo • CFX-CRESCENT705-900 Rev. P • 12/07

Page 18
Image 18