Step 9 Finishing

The following diagram shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace. See Figures 2 and 3 for other fireplace clearances. Only non-combustible materials may be used to cover the black fireplace front.

2 X 4 FRAMING

ALLOWED AT 43 5/8”

14.5”

NON-COMBUSTIBLE

MATERIAL

53”

38.5”

CEILING

18”

 

 

12”

 

 

 

 

 

11”

 

 

 

 

 

10”

 

 

 

 

 

9”

 

 

 

 

 

8”

 

 

12.5”

 

7”

 

 

 

 

 

 

 

 

6”

 

 

 

11.5”

13.5”

 

 

 

 

 

5”

 

 

 

9.5”

 

 

 

 

 

 

4”

 

 

 

10.5”

 

 

 

 

7.5”

 

3”

 

 

 

 

 

 

6.5”

 

 

 

 

5.5”

8.5”

4.5”

 

 

 

TOP FRONT EDGE

OF FIREPLACE

NOTE: Add 1 3/8” to these measurements if measuring from the top of the door.

FLOOR

CAUTION

Hearth Extensions

A hearth extension may be desirable for aesthetic reasons. However, ANSI or CAN/CGA testing standards do not require hearth extensions for gas fireplace appliances.

Figure 26. Min. Vertical and Max. Horizontal Dimensions of Combustibles above Fireplace

IF JOINTS BETWEEN THE FINISHED WALLS AND THE FIREPLACE SURROUND (TOP AND SIDES) ARE SEALED, A 300° F. MINIMUM SEALANT MATERIAL MUST BE USED. THESE JOINTS ARE NOT REQUIRED TO BE SEALED. ONLY NON-COMBUSTIBLE MATE- RIAL (USING 300° F. MINIMUM ADHESIVE, IF NEED-

ED) CAN BE APPLIED AS FACING TO THE FIREPLACE SURROUND. SEE THE DIAGRAM SHOWN BELOW.

HIGH TEMPERATURE

 

FINISH WALL MATERIAL

0

0

 

MAY BE COMBUSTIBLE

(300 F/149 C MIN.)

 

TOP SEAL JOINT

 

- TOP AND SIDES

 

 

 

34 1/2”

 

5 7/8”

 

1/2”

 

 

 

NON-COMBUSTIBLE

 

 

 

AREA

 

0

0

1/2”

HIGH TEMP (300 F/149 C MIN.) SIDE SEAL JOINT

Figure 27. Sealant Material

32

Heat & Glo • CFX-CRESCENT705-900 Rev. P • 12/07

Page 32
Image 32
Hearth and Home Technologies CFX-Crescent owner manual Hearth Extensions, Sealant Material