Use wall brackets to support vertical runs every 8 feet (2.4 m) above the fireplace flue outlet.
For Vertical Runs - The vent system must be supported every eight (8) feet (2.4 m) above the fireplace flue outlet by wall brackets.
To install support brackets for vertical runs:
•Attach wall brackets to the vent pipe and secure the wall bracket to the framing members with nails or screws.
WALL BRACKET
WALL STUD
| 8 FT. |
FLUE | (2.3m) |
| |
OUTLET |
|
1INCH MIN. (25.4m)
Figure 11. Installing Support Brackets 4. Install Firestops
For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the vent passes. The exterior firestop is not required at the termination cap for model
To install firestops for horizontal runs that pass through either interior or exterior walls:
•Cut a
Heat & Glo • | 19 |