Hearth and Home Technologies CFX-Crescent owner manual Approvals and Codes, Installation Codes

Models: CFX-Crescent

1 38
Download 38 pages 31.85 Kb
Page 7
Image 7

1

Approvals and Codes

Approval Listings Appliance Certification

and Codes

The Heat & Glo fireplace models discussed in this

 

Installers Guide have been tested to certification

 

standards and listed by the applicable laboratories.

 

 

 

 

MODEL

LABORATORY

TYPE

CERTIFICATION

STANDARD

CFX-Crescent

Underwriters

Direct Vent

ANSIZ21.50-2000•CSA2.22-M98

 

Laboratories

Gas Fireplace

 

 

 

 

 

Installation Codes

The fireplace installation must conform to local codes. Before installing the fireplace, consult the local building code agency to ensure that you are in compliance with all applicable codes, including permits and inspections.

In the absence of local codes, the fireplace installation must conform to the National Fuel Gas Code ANSI Z223.1 (in the United States) or the CAN/CGA- B149 Installation Codes (in Canada). The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes with the National Electric Code ANSI/NFPA No. 70 (in the United States), or to the CSA C22.1 Canadian Electric Code (in Canada).

This model may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada.

High Altitude Installations

U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2,000 feet in the U. S. A. and in Canada.

When installing this appliance at an elevation above 2,000 feet, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A. or 10% for elevations between 2000 and 4500 feet in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4,500 feet (in Canada), check with local authorities.

Heat & Glo Quality Systems registered by SGS ICS

7

Heat & Glo • CFX-CRESCENT705-900 Rev. P • 12/07

Page 7
Image 7
Hearth and Home Technologies CFX-Crescent owner manual Approvals and Codes, Approval Listings Appliance Certification