Hearth and Home Technologies CFX-Crescent owner manual Venting with eight 8 90 Elbows

Models: CFX-Crescent

1 38
Download 38 pages 31.85 Kb
Page 16
Image 16

Total H (Horizontal run) = 50 feet maximum.

Total V (Vertical run) = 46 feet maximum.

Any combination in between would be applicable.

COMBUSTION

AIR DUCT

40FT

MAXIMUM

COMBUSTION

AIR DUCT

18 FT

MAXIMUM

40 FT

MAXIMUM

Figure 8. Venting with eight (8) 90° Elbows

Unit could have up to eight elbows off the top, with a maximum of 50 feet hori- zontal before any vertical, however, a vertical run of 46 feet maximum could be introduced at any point of the horizontal run and even right off the top of the unit.

16

Heat & Glo • CFX-CRESCENT705-900 Rev. P • 12/07

Page 16
Image 16
Hearth and Home Technologies CFX-Crescent owner manual Venting with eight 8 90 Elbows