1.Apply the stove cement.
2.Line up the internal beads and slide pipe on. Note: Outer pipe slides into outer (cone shaped) collar 1/2 inch.
3.Fasten with four screws.
4.Apply the stove cement to outer collar joint.
B. Installing Vent Components
1.Attach the First Vent Component to the Starting Collars
To attach the first vent component to the starting collars of the fireplace:
•Apply a 3/8 inch (9.5 mm) bead of stove cement around the 4 inch (102 mm) fireplace starting collar.
•Slide the first vent section onto the collars attached to the top of the unit. Use four self tapping screws to secure the outer pipe to the outer collar.
•Apply a 3/8 inch (9.5mm) bead of stove cement around the 6 5/6 inch (168mm) outer collar.
STARTING
COLLAR
3/8” (9.5mm)
STOVE
SEALANT
BEAD
FIRST VENT
COMPONENT
1 INCH (25.4mm)
Figure 9. Attaching the First Vent Component to the Starting Collars
!WARNING: A 3/8 INCH (9.5 MM) BEAD OF STOVE CEMENT MUST BE PLACED AROUND THE 4 INCH (102 MM) FIREPLACE STARTING COLLAR BEFORE ATTACHING THE FIRST VENT COMPONENT. FAILURE TO SEAL THIS JOINT MAY CAUSE THE FIREPLACE TO OPERATE IMPROPERLY. SEE THE DIAGRAM .
Heat & Glo • | 17 |