Heat & Glo LifeStyle 6000 GDVFL, 6000 XLS Minimum Height from Roof to Lowest Discharge Opening

Models: 6000 GDVFL 6000 XLS

1 40
Download 40 pages 44.76 Kb
Page 24
Image 24

21

1.Attach the flashing and apply sealant around the edges of the flashing base.

2.Attach the storm collar over the flashing joint and apply sealant between the storm collar and vertical pipe.

To seal the roof hole, and to divert rain and snow from the vent system:

Attach a flashing to the roof using nails, and use a non-hardening mastic around the edges of the flashing base where it meets the roof.

Attach a storm collar over the flashing joint to form a water-tight seal. Place non-hardening mastic around the joint, between the storm collar and the vertical pipe.

Slide the termination cap over the end of the vent pipe and rotate the pipe clockwise 1/4 turn.

TERMINATION

CAP

Roof Pitch

H (min.) ft.

flat to 6/12

1.0

6/12 to 7/12

1.25

over 7/12 to 8/12

1.5

over 8/12 to 9/12

2.0

over 9/12 to 10/12

2.5

over 10/12 to 11/12

3.25

over 11/12 to 12/12

4.0

over 12/12 to 14/12

5.0

over 14/12 to 16/12

6.0

over 16/12 to 18/12

7.0

over 18/12 to 20/12

7.5

over 20/12 to 21/12

8.0

Figure 20. Minimum Height from Roof to Lowest Discharge Opening

Page 24
Image 24