Minimum Clearances from the Vent Pipe to

Combustible Materials

 

 

 

 

For Vertical

 

 

 

 

 

For Horizontal Sections

Sections

At Wall Firestops

 

 

 

 

 

 

 

 

 

 

 

Top

Bottom

Sides

 

Top

Bottom

Sides

 

 

 

 

 

 

 

 

 

 

 

3 inches

1 inch

1 inch

1 inch

2-1/2 inches

1/2 inch

1 inch

 

 

(75 mm)

(25 mm)

(25 mm)

(25 mm)

(63.7 mm)

(13 mm)

(25 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step 2

Framing the

Fireplace

For minimum clearances, see the direct vent termination clearance diagrams on pages 19 and 21 in this section.

Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommodate wall coverings and fireplace facing material. The diagram below shows framing reference dimensions.

5

CAUTION

MEASURE FIREPLACE DIMENSIONS, AND

 

VERIFY FRAMING METHODS AND WALL

 

COVERING DETAILS, BEFORE FRAMING

 

CONSTRUCTION BEGINS.

The framing headers may rest on the fireplace stand-offs.

 

 

 

 

B

 

 

 

 

C

 

 

 

 

A

 

 

 

 

Framing should be

 

 

 

 

constructed of 2 X 4

 

 

 

 

lumber or heavier.

Model

A

B

C

D

6000 Models

42

38-1/4

22

26-1/4

NOTE: DIMENSIONS SHOWN IN INCHES

Figure 3. Framing Dimensions

 

 

 

Page 8
Image 8