1.Apply the stove ce- ment.

2.Line up the internal beads and rotate the pipe sections clock- wise until locked.

3.Lock the vent compo- nents into place.

4.Check the seal on the rope gasket.

B. Installing Vent Components

1.Attach the First Vent Component to the Starting Collars

To attach the first vent component to the starting collars of the fireplace:

Apply a 3/8 inch (9.5 mm) bead of stove cement around the 5 inch (127 mm) fireplace starting collar.

Make sure that the fireplace rope gasket supplied with the fireplace seals between the first

8-5/8 inch (219 mm) vent component and the outer fireplace wrap.

Lock the vent components into place by sliding the concentric pipe sections with four (4) equally spaced interior beads into the fireplace collar or previously installed component end with four (4) equally spaced indented sections.

When the internal beads of each 8-5/8 inch

(219 mm) outer pipe line up, rotate the pipe section clockwise about one-quarter (1/4) turn. The vent pipe is now locked together.

The first 90° elbow installed in the vent system of a rear venting fireplace MUST BE in a vertical posi- tion.

STARTING

COLLAR

STOVE

SEALANT

BEAD

FIRST

3/8 INCH (9.5 mm)

VENT

 

COMPONENT

 

1 INCH (25.4 mm)

Figure 10. Attaching the First Vent Component to the Starting Collars

WARNING

A 3/8 INCH (9.5 MM) BEAD OF STOVE CEMENT MUST BE PLACED AROUND THE 5 INCH (127 MM) FIREPLACE STARTING COLLAR BEFORE ATTACHING THE FIRST VENT COMPONENT. FAILURE TO SEAL THIS JOINT MAY CAUSE THE FIREPLACE TO OPERATE IMPROPERLY. SEE THE DIAGRAM .

12

Page 15
Image 15
Heat & Glo LifeStyle 6000 XLS manual Installing Vent Components, Attach the First Vent Component to the Starting Collars