Heat & Glo LifeStyle 6000 XLS, 6000 GDVFL manual Installing Support Brackets 4. Install Firestops

Models: 6000 GDVFL 6000 XLS

1 40
Download 40 pages 44.76 Kb
Page 17
Image 17

Use wall brackets to support vertical runs every 8 feet (2.4 m) above the fireplace flue outlet.

NOTE

For Vertical Runs - The vent system must be supported every eight (8) feet (2.4 m) above the fireplace flue outlet by wall brackets.

To install support brackets for vertical runs:

Attach wall brackets to the vent pipe and secure the wall bracket to the framing members with nails or screws.

WALL BRACKET

WALL STUD

8 FT. (2.4 m)

FLUE

OUTLET

1 INCH MIN.

(25.4 mm)

Figure 12. Installing Support Brackets 4. Install Firestops

For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the vent passes.

Model DVK-01TRD does not need an exterior firestop on an exterior combustible wall.

To install firestops for horizontal runs that pass through either interior or exterior walls:

Cut a 12-inch by 12-inch (305 mm X 305 mm) hole through the wall. The center of the hole is one (1) inch (25.4 mm) above the center of the horizontal vent pipe.

14

Page 17
Image 17
Heat & Glo LifeStyle 6000 XLS, 6000 GDVFL manual Installing Support Brackets 4. Install Firestops