STANDING PILOT

DSI IGNITION

 

 

IGNITOR

3/8" (10 mm)

1/2" (13 mm)

3/16" (5 mm)

Figure 22. Gas Controls Systems

23

Step 6

The Gas

Supply Line

NOTE: Have the gas supply line installed by a qualified service technician in accordance with all building codes.

NOTE: Before the first firing of the fireplace, the gas supply line should be purged of any trapped air.

NOTE: Consult local building codes to properly size the gas supply line leading to the 1/2 inch

(13 mm) hook-up at the unit.

This gas fireplace is designed to accept a 1/2 inch (13 mm) gas supply line.

To install the gas supply line:

A listed 1/2 inch (13 mm) manual shut-off valve and a listed flexible gas connector are connected to the 1/2 inch (13 mm) inlet of the control valve.

A 1/8 inch (3 mm) N.P.T. plugged tapping, accessible for test gauge connection, should be provided for in the gas supply line leading to the unit’s shut-off valve.

Locate the gas line access hole in the outer casing of the fireplace.

Open the fireplace lower grille, insert the gas supply line through the gas line hole, and connect it to the shut-off valve.

When attaching the pipe, support the control so that the lines are not bent or torn.

After the gas line installation is complete, use a soap solution to carefully check all gas connections for leaks.

WARNING

DO NOT USE AN OPEN FLAME TO

CHECK FOR GAS LEAKS.

Page 26
Image 26
Heat & Glo LifeStyle 6000 GDVFL, 6000 XLS manual Step Gas Supply Line, Mm hook-up at the unit