Safety Alert Key:

DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.

WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.

CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Used to address practices not related to personal injury.

Table of Contents

A. Congratulations . . . . . . . . . . . . . . . . . 2 B. Limited Lifetime Warranty. . . . . . . . . . . . . . 5

1 Listing and Code Approvals

A. Appliance Certification. . . . . . . . . . . . . . . 7 B. Glass Specifications. . . . . . . . . . . . . . . . 7 C. BTU Specifications. . . . . . . . . . . . . . . . 7 D. High Altitude Installations. . . . . . . . . . . . . . 7

E.Non-Combustible Materials Specification. . . . . . . . . . . . . . 7

F.Combustible Materials Specification . . . . . . . . . 7

G.Electrical Codes. . . . . . . . . . . . . . . . . 7

H.Requirements for the Commonwealth of Massachusetts. . 8

User Guide

2 Operating Instructions

A. Gas Fireplace Safety. . . . . . . . . . . . . . . 9 B. Your Fireplace . . . . . . . . . . . . . . . . . . 9 C. Fan Kit (optional) . . . . . . . . . . . . . . . . 10 D. Clear Space. . . . . . . . . . . . . . . . . . 10 E. Decorative Doors and Fronts. . . . . . . . . . . . 10 F. Fixed Glass Assembly . . . . . . . . . . . . . . 10 G. Remote Controls, Wall Controls and Wall Switches. . . 10 H. IPI Battery Tray/Battery Installation . . . . . . . . . 11

I.Control Module Operation . . . . . . . . . . . . . 11

J.Before Lighting Fireplace. . . . . . . . . . . . . 11

K.Lighting Instructions (IPI). . . . . . . . . . . . . 12

L.After Fireplace is Lit. . . . . . . . . . . . . . . 13

M. Frequently Asked Questions . . . . . . . . . . . . 13

3 Maintenance and Service

A. Maintenance Tasks-Homeowner . . . . . . . . . . 14 B. Maintenance Tasks-Qualified Service Technician . . . . 15 C. Refractory, Grate and Valve Assembly Removal. . . . 16 D. Burner Identification/Verification. . . . . . . . . . . 17

Installer Guide

4 Getting Started

A.Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 18

B.Design and Installation Considerations . . . . . . . . 19

C.Tools and Supplies Needed. . . . . . . . . . . . 19

D.Inspect Appliance and Components. . . . . . . . . 19

5 Framing and Clearances

A. Selecting Appliance Location. . . . . . . . . . . . 20 B. Constructing the Appliance Chase. . . . . . . . . . 21 C. Clearances. . . . . . . . . . . . . . . . . . . 21 D. Mantel and Wall Projections. . . . . . . . . . . . 22

6 Termination Locations

A. Vent Termination Minimum Clearances. . . . . . . . 23

7 Vent Information and Diagrams

A. Approved Pipe. . . . . . . . . . . . . . . . . 25 B. Vent Table Key. . . . . . . . . . . . . . . . . 25 C. Use of Elbows . . . . . . . . . . . . . . . . . 25 D. Measuring Standards. . . . . . . . . . . . . . . 25 E. Vent Diagrams. . . . . . . . . . . . . . . . . 26

8 Vent Clearances and Framing

A. Pipe Clearances to Combustibles . . . . . . . . . . 37 B. Wall Penetration Framing. . . . . . . . . . . . . 37 C. Install the Ceiling Firestop . . . . . . . . . . . . . 38 D. Install Attic Insulation Shield. . . . . . . . . . . . 39 E. Installing the Optional Heat-Zone®Gas Kit . . . . . . . 39

9 Appliance Preparation

A.

Top Vent

. 40

B.

Rear Vent

41

C.Installing the Non-combustible Board. . . . . . . . . . . . . . . . 42

D.Securing and Leveling the Appliance. . . . . . . . . 42

10 Installing Vent Pipe (DVP and SLP Pipe)

A. Assemble Vent Sections (DVP Pipe Only). . . . . . . 43 B. Assemble Vent Sections (SLP Pipe Only). . . . . . . 44 C. Assemble Slip Sections. . . . . . . . . . . . . . 44 D. Secure the Vent Sections. . . . . . . . . . . . . 45 E. Disassemble Vent Sections. . . . . . . . . . . . 45

F.Install Decorative Ceiling Components (SLP only). . . . 46

G.Install Metal Roof Flashing. . . . . . . . . . . . . 47

H.Assemble and Install Storm Collar. . . . . . . . . . 47

I.Install Vertical Termination Cap . . . . . . . . . . . 48

J.Install Decorative Wall Components (SLP only). . . . . 48

K.Heat Shield Requirements for Horizontal Termination. . 48

L.Install Horizontal Termination Cap (DVP and SLP Pipe). 49

11 Gas Information

A. Fuel Conversion. . . . . . . . . . . . . . . . . 50 B. Gas Pressure. . . . . . . . . . . . . . . . . . 50 C. Gas Connection. . . . . . . . . . . . . . . . . 50 D. High Altitude Installations. . . . . . . . . . . . . 50

12 Electrical Information

A. Wiring Requirements. . . . . . . . . . . . . . . 51 B. IntelliFire PlusTM Ignition System Wiring. . . . . . . . 51 C. Optional Accessories Requirements . . . . . . . . . 51 D. Electrical Service and Repair. . . . . . . . . . . . 52

E.Junction Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . . 52

F.Wall Switch Installation for Fan (Optional). . . . . . . 52

Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T2165-900 Rev. S • 9/12

3

Page 3
Image 3
Heat & Glo LifeStyle 6000CL-IPI-T, 8000CL-IPI-S, 8000CL-IPI-T, 6000CL-IPI-S manual Table of Contents, User Guide

6000CL-IPI-T, 6000CL-IPI-S, 8000CL-IPI-S, 8000CL-IPI-T specifications

Heat & Glo has recognized the importance of creating both aesthetic and functional gas fireplaces that cater to the diverse needs of modern homeowners. Among their impressive lineup, the LifeStyle series stands out, particularly the models 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S, and 8000CL-IPI-T. Each of these units is designed to deliver exceptional performance, energy efficiency, and versatility.

The LifeStyle 6000CL-IPI-S and 6000CL-IPI-T models are distinguished by their contemporary linear design, offering a sleek aesthetic that perfectly complements modern interiors. Whether you choose the linear version with a sleek front or opt for one with traditional styling, both models provide flexibility in installation, making them suitable for various settings. The 8000CL-IPI series takes this further, offering larger fire viewing areas, which enhances the ambiance of any living space.

A notable feature across these models is the IntelliFire® automated ignition system, which provides reliable and efficient operation. This technology ensures that users can light their fireplaces with ease, eliminating the hassle of manual ignition. Additionally, the systems can be controlled via a remote, giving homeowners the convenience of adjusting flame height, heat output, and other features from a distance.

The fireplaces are designed with an emphasis on energy efficiency, making them an environmentally friendly choice. The advanced burner systems not only produce beautiful flames but also optimize fuel consumption. This means that homeowners can enjoy the warmth and beauty of a fire without the worry of excessive energy bills.

Another significant characteristic of the LifeStyle series is the array of finish options and media choices available. Whether you prefer traditional logs, contemporary glass media, or stone options, there is a choice to suit every style. The customizable nature of these fireplaces allows homeowners to create a focal point that reflects their personal taste.

Additionally, the easy maintenance of these models is a major selling point. With features like the clean-face design, users can spend more time enjoying their fireplaces rather than worrying about upkeep. The seamless cleanouts and accessibility ensure that servicing remains simple and straightforward.

Overall, the Heat & Glo LifeStyle 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S, and 8000CL-IPI-T gas fireplaces embody a perfect blend of innovation, efficiency, and style, making them a preferred choice for those looking to enhance their living spaces with the warmth of a fireplace.