Heat & Glo LifeStyle 6000CL-IPI-T Electrical Information, A. Wiring Requirements, Code CSA C22.1

Models: 6000CL-IPI-T 6000CL-IPI-S 8000CL-IPI-S 8000CL-IPI-T

1 82
Download 82 pages 63.04 Kb
Page 51
Image 51
12 Electrical Information

12 Electrical Information

A. Wiring Requirements

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric

Code CSA C22.1.

Wire the appliance junction box to 110-120 VAC. This is required for use of optional accessories (standing pilot ignition) or proper operation of the appliance (IntelliFire PlusTM ignition).

A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Low voltage and 110 VAC voltage cannot be shared within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire 110V to the valve or to the appliance wall switch. Incorrect wiring will damage controls.

B. IntelliFire PlusTM Ignition System Wiring

Wire the appliance junction box to 110 VAC for proper operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout.

Refer to Figure 12.1, IPI Wiring Diagram.

This appliance is equipped with an IntelliFire PlusTM control valve which operates on a 6 volt system.

Plug the 6 volt transformer plug into the appliance junction box to supply power to the unit OR install 4 AA cell batteries (not included) into the battery pack before use.

C. Optional Accessories Requirements

This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control.

Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories.

Hearth & Home Technologies recommends that IntelliFire PlusTM wireless controls be used for their features and functionality with the IntelliFire PlusTM ignition system.

 

 

 

 

 

OPTIONAL FAN

 

 

 

 

 

 

 

 

 

 

RC300 4.5V DC

 

 

 

 

 

FLAME

 

 

(AA X 3)

 

 

 

 

 

IGNITER

 

 

 

 

 

 

 

SENSE

 

 

 

 

 

 

 

 

 

 

 

TO JUNCTION

 

 

 

 

 

 

 

 

BOX (110V)

 

 

 

 

3 PRONG 110VAC

 

 

 

 

 

 

MODULE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GROUND

 

 

 

 

 

 

 

 

AUX300 MODULE

AUX2 NOT USED FOR 6000/8000 MODELS.

 

 

 

 

 

 

 

FAN

PROTECTIVE COVER INCLUDED

 

 

 

 

 

 

 

 

 

 

FLAME

 

 

 

AUX 1

AUX 2

TO JUNCTION

 

 

MODULATION

 

 

 

 

 

 

 

 

 

 

 

 

BOX 110VAC

 

 

 

 

 

 

BATTERY PACK

 

 

 

 

 

 

 

 

6V DC

 

 

 

ORANGE

GREEN

 

RED

 

 

 

 

 

 

BLACK

 

 

 

 

 

(PILOT)

(MAIN)

 

 

 

 

 

 

 

BROWN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED CONTROL

 

 

 

 

 

GROUND

 

 

 

 

 

 

 

 

 

 

 

REAR ACCENT

 

 

 

 

 

 

 

 

LIGHTING (X 2)

 

Figure 12.1 IPI Wiring Diagram

 

 

 

NOT USED FOR

 

 

 

 

 

 

6000CL/8000CL MODELS.

 

 

 

 

Heat & Glo

6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T

2165-900 Rev. S • 9/12

51

 

 

 

 

 

 

 

 

Page 51
Image 51
Heat & Glo LifeStyle 6000CL-IPI-T Electrical Information, A. Wiring Requirements, C. Optional Accessories Requirements