Heat & Glo LifeStyle 8000CL-IPI-S D. Electrical Service and Repair, E. Junction Box Installation

Models: 6000CL-IPI-T 6000CL-IPI-S 8000CL-IPI-S 8000CL-IPI-T

1 82
Download 82 pages 63.04 Kb
Page 52
Image 52
D. Electrical Service and Repair

D. Electrical Service and Repair

WARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation.

E. Junction Box Installation

If the box is being wired from the INSIDE of the appliance:

Remove the screw attaching the junction box/receptacle to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 12.2).

Pull the electrical wires from outside the appliance through the opening into the valve compartment and secure wires with a Romex connector. See Figure 12.2.

Make all necessary wire connections to the junction box/ receptacle and reattach the junction box/receptacle to the outer shell.

F. Wall Switch Installation for Fan (Optional)

If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.3):

The power supply for the appliance must be brought into a switch box.

The power can then be supplied from the switch box to the appliance using a minimum of 14-3 with ground wire.

At the switch box connect the black (hot) wire and red (switch leg) wire to the wall switch as shown.

At the appliance connect the black (hot), white (neutral) and green (ground) wires to the junction box as shown.

Add a 1/4 in. insulated female connector to the red (switch leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch connector (1/4 in. male) as shown.

 

Romex

 

Connector

 

14/2WG

 

Cover Plate

 

outside firebox

WHT

 

BLK

 

WHT

 

BLK

Copper

 

GRN wire

ground attached

to GRN screw with

inside box

 

GRN wire

NOTICE: DO NOT wire

110 VAC to wall switch.

Figure 12.2 Junction Box Detail

 

Minimum 14-3 AWG

 

Switch

 

 

with Ground

 

 

 

Red

 

 

Black

Black

 

White

White

Junction Box

Green

Green

Red Black White Green

 

 

 

Switch Box

Power

 

Supply

 

 

 

 

Wires

 

Knockout

 

Red

 

 

Figure 12.3 Junction Box Wired to Wall Switch or BC10

52

Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T2165-900 Rev. S • 9/12

Page 52
Image 52
Heat & Glo LifeStyle 8000CL-IPI-S D. Electrical Service and Repair, E. Junction Box Installation, NOTICE: DO NOT wire