Henny Penny OE-30X, OG-30X manual Drain shortening from the frypot

Models: OG-30X OE-30X

1 154
Download 154 pages 47.36 Kb
Page 50
Image 50
2.Drain shortening from the frypot.

Before following these steps, place POWER switch to the OFF position, and unplug the power cord or open the wall circuit breaker, or electrical shock could result. Be aware that the other controls will HAVE power.

1.If the tube is broken or cracked, the control will open, shut- ting off electrical power. The control cannot be reset.

2.Drain shortening from the frypot.

3.Remove control panel, per section 6-3.

4.Loosen small inside screw nut on capillary tube.

5.Remove capillary bulb from bulb holder inside the frypot.

6.Straighten the capillary tube.

7.Remove larger outside nut that threads into pot wall.

8.Remove the two screws that secures the high limit to the high limit bracket.

9.Loosen clamp on capillary tube.

12.Uncoil capillary line, starting at capillary tube, and insert through frypot wall.

To avoid electrical shock or other injury, the capillary line must run under and away from all electrical power wires and ter- minals. The tube must never be in such a position where it could accidentally touch the electrical power terminals.

13.Carefully bend the capillary bulb and tube toward bulb holder on heating elements.

14.Slip capillary bulb into bulb holder located on heating elements. Pull excess capillary line from pot and tighten nut into frypot wall;

Page 50