5.Install the control panel per section 6-3.

6-8.

NT

s

4.Connect the labeled wires to their respective positions.

5.Install the control panel per section 6-3.

6.Reconnect power to the fryer and test the fryer for proper operation.

The gas model fryers have gas burner assemblies per cookpot consisting of Burner Casting, Orifices, Thermocouples, Pilot Holders, Main Gas Valve Controls, and Gas Safety Solenoid.

Also, each burner has a main gas shut-off valve, so all burners do not have to be shut down to work on one burner assembly.

If converting from natural gas to propane or from propane to natural gas, conversion must be done by a qualified service technician.

To avoid personal injury or property damage, before starting this procedure, move the power switch to the “OFF” position, and unplug power cord from wall receptacle. Turn off the gas supply to the frypot to be worked on, or a possible explosion could result.