Henny Penny OE-30X, OG-30X manual Remove power supplied to the unit

Models: OG-30X OE-30X

1 154
Download 154 pages 47.36 Kb
Page 72
Image 72
1. Remove power supplied to the unit.

318TO 112 INCH

PILOT

ace

13.Check for gas leak at the gas control valve and main gas valve per step 11 of this section, If there are no leaks, eon- tinue to step 14.

If a leak is detected, shut off gas valves and repair leak. Escaping gas could cause an explosion, and personal injury and property damage could result.

14.With the gas cock dial at PILOT, depress the dial and light the pilot burner per section 6-11.

The Gas Safety Solenoid is a gas line shut off, to the burner, if the high limit trips. When the high limit is reset, the solenoid should open.

If the high limit is closed, the pilot lit, and the gas valve checks out, the gas solenoid needs replaced.

A “click” may be heard if solenoid is working properly.

1. Remove power supplied to the unit.

Disconnect power supplied to the unit by unplugging the power cord, or turning off the wall circuit breaker or fuse, or electrical shock could result.

2.Turn the gas shut off to the off position (see operations section).

3.Open door to bottom of unit.

4.Remove control panel per section 6-3.

5.Remove gas burner assembly per section 6-9.

6.Remove solenoid from burner assembly.

7.Reinstall burner assembly per section 6-9.

Page 72
Image 72
Henny Penny OE-30X, OG-30X manual Remove power supplied to the unit