5.Remove probe as described in section 6-4.

213

5.Remove probe as described in section 6-4.

6.Loosen small inside screw nut on capillary tube.

7.Remove capillary bulb from bulb holder on inside of frypot.

8.Remove larger outside screw nut that threads into “Y” fitting.

9.Cut the capillary bulb on the inside of cookpot, and remove the capillary from unit.

10.Remove capillary from clamp on shroud.

11.Remove the two screws that secures the high limit to bracket and remove the control from the unit.

12.Insert capillary of new high limit, through “Y” fitting.

13.Put pipe sealant on threads and screw “Y” fitting back into fitting in frypot.

14.Insert new control on bracket.

15.Carefully bend the capillary bulb towards the bulb holder and insert into holder.

16.Pull excess capillary line from pot and tighten nut into “Y” fitting.

Be sure capillary bulb of high limit is located close to frypot wall. Capillary bulb and line should be positioned as not to in- terfere with basket, or when cleaning the frypot wall, or damage to capillary tube could result.

17.With excess capillary line pulled out tighten smaller nut.

18.Clamp capillary tube down to shroud.

To avoid electrical shock or other injury, the capillary tube must run under and away from all electrical power wires and ter- minals. The tube must never be in such a position where it could accidentally touch the electrical power terminals.

19.Replace probe, per section 6-4.

20.Replace front panel.

21.Refill with shortening.