“B”Function Defaults
Func.
Code
Name/
SRWDisplay Description
Run
Mode
Edit
-FE
(EU)
-FU
(USA)Units
Selection of automatic restart
mode
B001
IPS POWR ALM
Select inverter restart method,
Four option codes:
00}Alarm output after trip, no
automatic restart
01}Restart at 0Hz
02}Resume operation after
frequency pull-in
03}Resume previous freq. after
freq. pull-in, then decelerate
to stop and display trip info
U00 00
Allowable under-voltage
power failure time
B002
IPS Time 0001.0s
The amount of time a power
input under-voltage can occur
without tripping the power
failure alarm. Range is 0.3 to 25
sec. If under-voltage exists longer
than this time, the inverter trips,
even if the restart mode is
selected.
U1.0 1.0 sec.
Retry wait time before motor
restart
B003
IPS Wait 0001.0s
Time delay after under-voltage
condition goes away, before the
inverter runs motor again.
Range is 0.3 to 100 seconds.
U1.0 1.0 sec.
Instantaneous power failure /
under-voltage trip alarm
enable
B004
IPS TRIP OFF
Two option codes:
00}Disable
01}Enable
U00 00
Number of restarts on power
failure / under-voltage trip
events
B005
IPS RETRY 16
Two option codes:
00}Restart 16 times
01}Always restart
U00 00

Frequency Pull-in Restart

“B”Function Defaults
Func.
Code
Name/
SRWDisplay Description
Run
Mode
Edit
-FE
(EU)
-FU
(USA)Units
Start freq to be used in case
of frequency pull-in restart
B011
FSch Md CUTOFF
Three option codes:
00}freq at previous shutoff
01}start from max. Hz
02}start from set frequency
U00 00
Deceleration rate of
frequency pull-in restart
setting
B029
FSch CNS 0000.5s
Sets the deceleration rate when
frequency pull-in restart, range is
0.1 to 3000.0, resolution 0.1
U0.5 0.5 sec.
Current level of frequency
pull-in restart setting
B030
FSch LVL 002.60A
Sets the current level of
frequency pull-in restart, range is
0.2*inverter rated current to
2.0*inverter rated current,
resolution 0.1
URated
current
A

333

Configuring Drive
Parameters
3 33