“B”Function Defaults
Func.
Code
Name/
SRWDisplay Description
Run
Mode
Edit
-FE
(EU)
-FU
(USA)Units
[AM] analog signal gainB080
AM-Adj 00100%
Adjust of analog output at
terminal [AM],
range is 0 to 255
9100. 100.
Start frequency adjustmentB082
fmin 0000.5Hz
Sets the starting frequency for
the inverter output, range is 0.5
to 9.9 Hz
U0.5 0.5 Hz
Carrier frequency settingB083
Carrier 0003.0
Sets the PWM carrier (internal
switching frequency), range is 2.0
to 12.0 kHz
U3.0 3.0 kHz
Initialization mode
(parameters or trip history)
B084
INIT Mode TRP
Select the type of initialization to
occur, three option codes:
00}Trip history clear
01}Parameter initialization
02} Trip history clear and
parameter initialization
U00 00
Country for initializationB085
INIT Slct EU
Select default parameter values
for country on initialization,
three option codes:
00}Japan
01}Europe
02}US
U01 02
Frequency scaling conversion
factor
B086
Cnv Gain 0001.0
Specify a constant to scale the
displayed frequency for D007
monitor, range is 0.1 to 99.9
91.0 1.0
STOP key enableB087
STP Key ON
Select whether the STOP key on
the keypad is enabled,
two option codes:
00}Enabled
01}Disabled
U00 00