“C” Group: Intelligent Terminal Functions

The five input terminals [1],[2],[3],[4], and [5] can be configured for any of 31 differentfunctions. The next two tables show how to configure the five terminals. The inputs arelogical, in that they are either OFF or ON. We define these states as OFF=0, and ON=1.The inverter comes with default options for the five terminals. These settings areinitially unique, each one having its own setting. Note that European and US versionshave different default settings. You can use any option on any terminal, and even usethe same option twice to create a logical OR (though usually not required).NOTE: Terminal [5] has the ability to be a logical input, and to be an analog input for athermistor device when PTC function (option code 19) is assigned to that terminal.
Input Terminal Configuration
Functions and Options – The
function codes
in the following table let you assign one oftwenty eight options to any of the five logic inputs for the X200 inverters. The functionsC001 through C005 configure the terminals [1] through [5] respectively. The “value” ofthese particular parameters is not a scalar value, but it is a discrete number that selectsone option from many available
options
.For example, if you set function C001=00, you have assigned option 00 (Forward Run) toterminal [1]. The option codes and the specifics of how each one works are in Chapter 4.
“C”Function Defaults
Func.
Code
Name/
SRWDisplay Description
Run
Mode
Edit
-FE
(EU)
-FU
(USA)Units
Terminal [1] functionC001
IN-TM 1 FW
Select input terminal [1] function, 30
options(see next section) U
Terminal [1] function,
2nd motor
C201
2IN-TM 1 FW
Select input terminal [1] function for
2nd motor, 30 options(see next
section)
U
00
[FW]
00
[FW]
Terminal [2] functionC002
IN-TM 2 RV
Select input terminal [2] function, 30
options(see next section) U
Terminal [2] function,
2nd motor
C202
2IN-TM 2 RV
Select input terminal [2] function for
2nd motor, 30 options(see next
section)
U
01
[RV]
01
[RV]
Terminal [3] functionC003
IN-TM 3 AT
Select input terminal [3] function, 30
options(see next section) U02
[CF1]
16
[AT]
Terminal [3] function,
2nd motor
C203
2IN-TM 3 AT
Select input terminal [3] function for
2nd motor, 30 options(see next
section)
U02
[CF1]
16
[AT]
Terminal [4] functionC004
IN-TM 4 USP
Select input terminal [4] function, 30
options(see next section) U
Terminal [4] function,
2nd motor
C204
2IN-TM 2 USP
Select input terminal [4] function for
2nd motor, 30 options(see next
section)
U
03
[CF2]
13
[USP]
Terminal [5] functionC005
IN-TM 5 2CH
Select input terminal [5] function, 30
options(see next section) U
Terminal [5] function,
2nd motor
C205
IN-TM 5 2CH
Select input terminal [5] function for
2nd motor, 30 options(see next
section)
U
18
[RS]
18
[RS]

349

Configuring Drive
Parameters
3 49