Func.

 

 

 

Default Value

Set

 

Name / Description

–FE2 / –FU2 /

Code

 

Value

 

 

 

–FR

 

 

 

 

 

 

 

 

 

 

 

 

 

A062/

Frequency lower limit setting

0.00

 

A262

 

 

 

 

 

 

 

 

 

A063

Jump (center) frequency setting

0.00

 

A065

 

 

 

 

 

A067

 

 

 

 

 

 

 

 

 

A064

Jump (hysteresis) frequency width setting

0.50

 

A066

 

 

 

 

 

A068

 

 

 

 

 

 

 

 

 

A069

Acceleration pause frequency setting

0.00

 

 

 

 

 

A070

Acceleration pause time setting

0.0

 

 

 

 

 

 

A071

PID Enable

 

00

 

 

• 00 PID operation OFF

 

 

 

• 01 PID operation ON

 

 

 

 

 

 

 

A072

PID proportional gain

 

1.0

 

 

 

 

 

A073

PID integral time constant

1.0

 

 

 

 

 

A074

PID derivative time constant

0.0

 

 

 

 

 

 

A075

PV scale conversion

 

1.00

 

 

 

 

 

 

A076

PV source setting:

 

00

 

 

00 [OI] terminal (current input)

 

 

 

01 [O] terminal (voltage input)

 

 

 

 

 

 

 

A081

AVR function select

 

00 / 00 / 02

 

 

• 00 AVR enabled

• 01 AVR disabled

 

 

 

• 02 AVR enabled except during decel

 

 

 

 

 

 

 

A082

AVR voltage select

 

230 230 200

 

 

 

 

 

400 460 400

 

 

 

 

 

A085

Operation mode selection

00

 

 

• 00 Normal operation

 

 

 

 

• 01 Energy-saver operation

 

 

 

 

 

 

A086

Energy saving mode tuning

50.0

 

 

 

 

 

A092/

Acceleration (2) time setting

15.0

 

A292

 

 

 

 

 

 

 

 

 

A093/

Deceleration (2) time setting

15.0

 

A293

 

 

 

 

 

 

 

 

 

A094/

Select method to switch to Acc2/Dec2

00

 

A294

profile

 

 

 

 

• 00 2CH input from terminal

 

 

 

01 transition frequency

 

 

 

 

 

 

A095/

Acc1 to Acc2 frequency transition point

0.0

 

A295

 

 

 

 

 

 

 

 

 

A096/

Dec1 to Dec2 frequency transition point

0.0

 

A296

 

 

 

 

 

 

 

 

 

 

 

17