Func.

 

 

Default Value

Set

 

Name / Description

–FE2 / –FU2 /

Code

 

Value

 

 

–FR

 

 

 

 

 

 

 

 

 

 

 

 

b022

Overload restriction setting

Rated current x

 

 

 

 

1.20 / 1.10 /

 

 

 

 

1.20

 

 

 

 

 

b023

Deceleration rate at overload restriction

1.00 / 15.00 /

 

 

 

 

1.00

 

 

 

 

 

b024

Overload restriction operation mode (2)

01

 

 

• 00 Disabled

 

 

 

• 01 Enabled for accel and constant speed

 

 

 

• 02 Enabled for constant speed only

 

 

 

 

 

 

b025

Overload restriction setting (2)

Rated current

 

 

 

 

x 1.20

 

 

 

 

 

b026

Deceleration rate at overload restriction (2)

1.00

 

 

 

 

 

b031

Software lock mode selection

01

 

 

• 00 Low-level access, [SFT] blocks edits

 

 

 

• 01 Low-level access, [SFT] blocks edits

 

 

 

(except F001 and Multi-speed parameters)

 

 

 

• 02 No access to edits

 

 

 

• 03 No access to edits except F001 and

 

 

 

Multi-speed parameters

 

 

 

• 10 High-level access, including b031

 

 

 

 

 

 

b034

Run/power on warning time

0.

 

 

 

 

 

b035

Rotational direction restriction

00

 

 

• 00 Enable for both directions

 

 

 

• 01 Enable for forward only

 

 

 

• 02 Enable for reverse only

 

 

 

 

 

 

b036

Reduced voltage start selection

06

 

 

• 00 Short

 

 

 

01, 02, 03, 04, 05 (middle)

 

 

 

• 06 Long

 

 

 

 

 

 

b037

Function code display restriction

00

 

 

• 00 Display all

 

 

 

• 01 Display only utilized functions

 

 

 

• 02 Display user-selected functions only

 

 

 

(configure with U01 to U12)

 

 

 

 

 

 

b080

[AM] terminal analog meter adjustment

180

 

 

 

 

 

b081

[FM] terminal analog meter adjustment

60

 

 

 

 

 

b082

Start frequency adjustment

0.50

 

 

 

 

 

b083

Carrier frequency setting

3.0

 

 

 

 

 

b084

Initialization mode (parameters or trip

00

 

 

history)

 

 

 

00 Trip history clear

 

 

 

01 Parameter initialization

 

 

 

02 Trip history clear and parameter initial-

 

 

 

ization

 

 

 

 

 

 

 

20