Analog Output Function Listing
The following table shows all seven functions available for assignment to the three analog output terminals:
•Terminal [FM], option set by C027
•Terminal [AM], option set by C028
•Terminal [AMI], option set by C029
Option | Function | Description | Corresponding | |
Code | Name | Signal Range | ||
| ||||
|
|
|
| |
|
|
|
| |
00 | Output | Actual motor speed, | 0 to max. frequency in Hz | |
| frequency | represented by PWM |
| |
|
| signal |
| |
|
|
|
| |
01 | Output current | Motor current (% of | 0 to 200% | |
|
| maximum rated output |
| |
|
| current), represented by |
| |
|
| PWM signal |
| |
|
|
|
| |
03 | Digital output | Output frequency (avail- | 0 to max. frequency in Hz | |
| frequency | able only at FM output) |
| |
|
|
|
| |
04 | Output voltage | Rated output voltage to | 0 to 100% | |
|
| motor |
| |
|
|
|
| |
05 | Input power | Rated input power | 0 to 200% | |
|
|
|
| |
06 | Electronic | Percentage of electronic | 0 to 100% | |
| thermal | overload attained |
| |
| overload |
|
| |
|
|
|
| |
07 | LAD | Internal ramp generator | 0 to max. frequency in Hz | |
| frequency | frequency |
| |
|
|
|
|
30