Analog Output Function Listing

The following table shows all seven functions available for assignment to the three analog output terminals:

Terminal [FM], option set by C027

Terminal [AM], option set by C028

Terminal [AMI], option set by C029

Option

Function

Description

Corresponding

Code

Name

Signal Range

 

 

 

 

 

 

 

 

 

00

Output

Actual motor speed,

0 to max. frequency in Hz

 

frequency

represented by PWM

 

 

 

signal

 

 

 

 

 

01

Output current

Motor current (% of

0 to 200%

 

 

maximum rated output

 

 

 

current), represented by

 

 

 

PWM signal

 

 

 

 

 

03

Digital output

Output frequency (avail-

0 to max. frequency in Hz

 

frequency

able only at FM output)

 

 

 

 

 

04

Output voltage

Rated output voltage to

0 to 100%

 

 

motor

 

 

 

 

 

05

Input power

Rated input power

0 to 200%

 

 

 

 

06

Electronic

Percentage of electronic

0 to 100%

 

thermal

overload attained

 

 

overload

 

 

 

 

 

 

07

LAD

Internal ramp generator

0 to max. frequency in Hz

 

frequency

frequency

 

 

 

 

 

30