Analog Input Configuration
The following tables show the parameter settings required for various analog input signal types.
|
|
| External | Trim | Reverse | |
A006 | A005 | [AT] | Frequency | Frequency | available | |
Command | Command | (bipolar | ||||
|
|
| ||||
|
|
| Input | Input | input) | |
|
|
|
|
|
| |
|
|
|
|
|
| |
00 | 00 | OFF | [O] — [L] | ✘ | ✘ | |
|
|
|
|
|
| |
|
| ON | [OI] — [L] | ✘ | ✘ | |
|
|
|
|
|
| |
| 01 | OFF | [O] — [L] | ✘ | ✘ | |
|
|
|
|
|
| |
|
| ON | [O2] — [L] | ✘ | ✔ | |
|
|
|
|
|
| |
01 | 00 | OFF | [O] — [L] | [O2] — [L] | ✘ | |
|
|
|
|
|
| |
|
| ON | [OI] — [L] | [O2] — [L] | ✘ | |
|
|
|
|
|
| |
| 01 | OFF | [O] — [L] | [O2] — [L] | ✘ | |
|
|
|
|
|
| |
|
| ON | [O2] — [L] | ✘ | ✔ | |
|
|
|
|
|
| |
02 | 00 | OFF | [O] — [L] | [O2] — [L] | ✔ | |
|
|
|
|
|
| |
|
| ON | [OI] — [L] | [O2] — [L] | ✔ | |
|
|
|
|
|
| |
| 01 | OFF | [O] — [L] | [O2] — [L] | ✔ | |
|
|
|
|
|
| |
|
| ON | [O2] — [L] | ✘ | ✔ | |
|
|
|
|
|
|
The table below applies when the [AT] input function is not assigned to any intelligent input terminal. The A005 setting, normally used in conjunction with an [AT] input, is ignored.
|
|
| External | Trim | Reverse | |
A006 | A005 | [AT] | Frequency | Frequency | available | |
Command | Command | (bipolar | ||||
|
|
| ||||
|
|
| Input | Input | input) | |
|
|
|
|
|
| |
|
|
|
|
|
| |
00 | — | (not | [O2] — [L] | ✘ | ✔ | |
|
| assigned |
|
|
| |
01 | — | Summation of | [O2] — [L] | ✘ | ||
to any | ||||||
|
| [O] — [L] and |
|
| ||
|
| input |
|
| ||
|
| [OI] — [L] |
|
| ||
|
| termi- |
|
| ||
|
| nal) |
|
|
| |
02 | — | Summation of | [O2] — [L] | ✔ | ||
| ||||||
|
|
| [O] — [L] and |
|
| |
|
|
| [OI] — [L] |
|
| |
|
|
|
|
|
|
29