“P” Group: Expansion Card Functions

Func.

 

Default Value

Set

Name / Description

–FE2 / –FU2 /

Code

Value

 

–FR

 

 

 

 

 

 

 

 

 

 

 

P001

Operation mode on expansion card #1 error

00

 

 

• 00 Trip (stop motor)

 

 

 

• 01 Continuous operation

 

 

 

 

 

 

P002

Operation mode on expansion card #2 error

00

 

 

• 00 Trip (stop motor)

 

 

 

• 01 Continuous operation

 

 

 

 

 

 

P044

DeviceNet comm watchdog timer

1.00

 

 

 

 

 

P045

Inverter action on DeviceNet comm error

01

 

 

• 00 Trip

 

 

 

• 01 Decelerate and trip

 

 

 

• 02 Hold last speed

 

 

 

• 03 Free run stop

 

 

 

• 04 Decelerate and stop

 

 

 

 

 

 

P046

DeviceNet polled I/O: Output instance

21

 

 

number

 

 

 

 

 

 

P047

DeviceNet polled I/O: Input instance

71

 

 

number

 

 

 

 

 

 

P048

Inverter action on DeviceNet idle mode

01

 

 

• 00 Trip

 

 

 

• 01 Decelerate and trip

 

 

 

• 02 Hold last speed

 

 

 

• 03 Free run stop

 

 

 

• 04 Decelerate and stop

 

 

 

 

 

 

P049

DeviceNet motor poles setting for RPM

0

 

 

 

 

 

P050

• Output frequency on analog reference

00 / 00 / —

 

 

signal loss (–xFE2/–xFU2 models only)

 

 

 

• 00 Output freq. forced to 0 Hz; 500ms

 

 

 

wait to recover

 

 

 

• 01 Output freq. forced to 0 Hz; no wait to

 

 

 

recover

 

 

 

• 02 Output freq. forced to max. freq. A004

 

 

 

• 03 Output freq. forced to A020/A220

 

 

 

 

 

 

25