Hobart Welding Products OM-240 438B manual Selecting Weld Cable Sizes, 150 ft 200 ft 250 ft, 500

Models: OM-240 438B

1 72
Download 72 pages 14.86 Kb
Page 30
Image 30

. A complete Parts List is available at wwwHobartWelders.com

5-9. Selecting Weld Cable Sizes*

NOTICE − The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is 100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine cable size.

Weld Output

Terminals

! Turn off power before connecting to weld output terminals.

!Do not use worn, damaged, under- sized, or poorly spliced cables.

 

Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit

 

 

 

Not Exceeding***

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 ft (30 m) or Less

150 ft

200 ft

250 ft

300 ft

 

350 ft

400 ft

 

(45 m)

(60 m)

(70 m)

(90 m)

 

(105 m)

(120 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Welding

10 − 60%

60 − 100%

 

 

 

 

 

 

 

Duty

Duty

 

10 − 100% Duty Cycle

 

 

Amperes

 

 

 

Cycle

Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

4 (20)

4 (20)

4 (20)

3 (30)

2 (35)

1 (50)

 

1/0 (60)

1/0 (60)

 

 

 

 

 

 

 

 

 

 

150

3 (30)

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

 

3/0 (95)

3/0 (95)

 

 

 

 

 

 

 

 

 

 

200

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

 

4/0 (120)

4/0 (120)

 

 

 

 

 

 

 

 

 

 

250

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

 

2 ea. 2/0

2 ea. 2/0

 

(2x70)

(2x70)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

 

2 ea. 3/0

2 ea. 3/0

(2x70)

 

(2x95)

(2x95)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

350

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 3/0

 

2 ea. 3/0

2 ea. 4/0

(2x70)

(2x95)

 

(2x95)

(2x120)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 3/0

 

2 ea. 4/0

2 ea. 4/0

(2x70)

(2x95)

 

(2x120)

(2x120)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 3/0

2 ea. 4/0

 

3 ea. 3/0

3 ea. 3/0

(2x70)

(2x95)

(2x120)

 

(3x95)

(3x95)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*This chart is a general guideline and may not suit all applications. If cables overheat, use next size larger cable.

**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

 

( ) = mm2 for metric use

S-0007-F