8-7. Overload Protection (Subaru-Powered Units)

! Stop engine. Disconnect negative (−) battery cable.

1 Fuse F1 (See Section 11-1)

F1 protects the weld excitation winding from overload. If F1 opens, weld output stops or is low.

2 Fuse F2 (See Section 11-1)

F2 protects the generator power

3excitation winding from overload. If

F2 opens, generator power output stops or is low.

21

.Fuses F1, F2 located on

bracket behind left side panel.

. Fuse F6 located in harness behind left side door.

3 Fuse F6 (See Section 11-1)

F6 protects the engine wiring sys- tem from overload. If F6 opens, engine will not crank.

Replace any open fuses. Reinstall cover before operating.