Hobart Welding Products OM-240 438B Welding Troubleshooting, Generator Power Troubleshooting

Models: OM-240 438B

1 72
Download 72 pages 14.86 Kb
Page 48
Image 48

. A complete Parts List is available at wwwHobartWelders.com

SECTION 10 − TROUBLESHOOTING

10-1. Welding Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trouble

 

 

 

Remedy

 

 

 

Low or no weld output; generator pow-

 

Check control settings.

er output okay at ac receptacles.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check weld connections.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check fuse F1, and replace if open (see Section 8-7or 9-6).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check brushes, slip rings, capacitor C1, and integrated rectifi-

 

 

 

 

 

 

 

 

 

ers SR2 and SR3.

 

 

No weld output or generator power out-

Be sure all equipment is disconnected from receptacles when starting unit.

put at ac receptacles.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check fuses F1 and F2, and replace if open (see Section 8-7or 9-6).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check plug PLG6 connection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check brushes, slip rings, capacitor C1, and integrated rectifi-

 

 

 

 

 

 

 

 

 

ers SR2 and SR3.

 

 

 

Low weld output.

 

Check fuse F1, and replace if open (see Section 8-7or 9-6).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check control settings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check engine speed, and adjust if necessary (see Section 8-6or 9-5).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Service air cleaner according to engine manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check brushes, slip rings, capacitor C1, and integrated rectifi-

 

 

 

 

 

 

 

 

 

ers SR2 and SR3.

 

 

 

High weld output.

 

Check control settings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check engine speed, and adjust if necessary (see Section 8-6or 9-5).

 

 

 

Erratic weld output.

 

Check control settings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tighten and clean connections to electrode and workpiece.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use dry, properly-stored electrodes for Stick and TIG welding.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove excessive coils from weld cables.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean and tighten connections both inside and outside welding generator.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check engine speed, and adjust if necessary (see Section 8-6or 9-5).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifiers SR2, SR3.

 

 

 

 

 

 

 

 

 

 

 

 

10-2. Generator Power Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trouble

 

 

 

Remedy

 

 

 

No or low generator power output at ac

 

Reset supplementary protectors (see Section 7-1).

receptacles; weld output okay.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check fuse F2, and replace if open (see Section 8-7or 9-6).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check plug PLG6 connection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifier SR3.

 

 

 

 

 

 

 

 

 

 

 

 

OM-240 438 Page 44

Page 48
Image 48
Hobart Welding Products OM-240 438B manual Welding Troubleshooting, Generator Power Troubleshooting, Trouble Remedy