Selection

Setting

Serial Command

Page

* Indicates default

# Indicates a numeric entry

 

 

 

 

 

 

 

 

 

 

In-Stand and Out-of-Stand Settings

In-Stand Defaults

AISDFT

4-6

 

 

 

 

 

Out-of-Stand Defaults

AOSDFT

4-6

 

 

 

 

 

Presentation Mode Out-of-Stand

PAPPM1

4-7

 

 

 

 

 

Presentation Mode with CodeGate Out-of-

PAPPM2

4-7

 

Stand

 

 

 

 

 

 

 

Manual Activation Mode Off In-Stand

AISMEN0

4-7

 

 

 

 

 

*Manual Activation Mode On In-Stand

AISMEN1

4-7

 

 

 

 

 

Manual Activation Mode Off Out-of-Stand

AOSMEN0

4-7

 

 

 

 

 

*Manual Activation Mode On Out-of-Stand

AOSMEN1

4-7

 

 

 

 

 

Do Not End Manual Activation After Good

AISMGD0

4-7

 

Read In-Stand

 

 

 

 

 

 

 

*End Manual Activation After Good Read

AISMGD1

4-8

 

In-Stand

 

 

 

 

 

 

 

Do Not End Manual Activation After Good

AOSMGD0

4-8

 

Read Out-of-Stand

 

 

 

 

 

 

 

*End Manual Activation After Good Read

AOSMGD1

4-8

 

Out-of-Stand

 

 

 

 

 

 

 

Laser Timeout - Button Hold In-Stand

AISMPT#####

4-8

 

(Range 1 - 65525) *5000 ms

 

 

 

 

 

 

 

Laser Timeout - Button Release In-Stand

AISMRT#####

4-8

 

(Range 1 - 65525) *0 ms

 

 

 

 

 

 

 

Laser Timeout - Button Hold Out-of-Stand

AOSMPT#####

4-8

 

(Range 1 - 65525) *5000 ms

 

 

 

 

 

 

 

Laser Timeout - Button Release Out-of-

AOSMRT#####

4-8

 

Stand

 

 

 

(Range 1 - 65525) *0 ms

 

 

 

 

 

 

 

*CodeGate Off In-Stand

AISCGD0

4-9

 

 

 

 

 

CodeGate On In-Stand

AISCGD1

4-9

 

 

 

 

 

CodeGate Off Out-of-Stand

AOSCGD0

4-9

 

 

 

 

 

*CodeGate On Out-of-Stand

AOSCGD1

4-9

 

 

 

 

 

*Button Function Off

BTNFNC0

4-9

 

 

 

 

 

Button Function On

BTNFNC1

4-9

 

 

 

 

 

Object Detection Mode Off In-Stand

AISOEN0

4-9

 

 

 

 

 

Object Detection Mode On Out-of-Stand

AOSOEN1

4-10

 

 

 

 

 

*Object Detection Mode Off Out-of-Stand

AOSOEN0

4-9

 

 

 

 

 

*Object Detection Mode On In-Stand

AISOEN1

4-10

 

 

 

 

 

Do Not End Object Detection After Good

AISOGD0

4-10

 

Read In-Stand

 

 

 

 

 

 

 

*End Object Detection After Good Read

AISOGD1

4-10

 

In-Stand

 

 

 

 

 

 

 

Do Not End Object Detection After Good

AOSOGD0

4-10

 

Read Out-of-Stand

 

 

 

 

 

 

 

*End Object Detection After Good Read

AOSOGD1

4-10

 

Out-of-Stand

 

 

 

 

 

 

 

Object Detection Laser Timeout In-Stand

AISODT#####

4-11

 

(Range 1 - 65525) *5000 ms

 

 

 

 

 

 

10 - 13