Installing the Switch

Installation Procedures

1. Prepare the Installation Site

Cabling Infrastructure - Ensure the cabling infrastructure meets the necessary network specifications. See Appendix B “Cabling and Technology Information” for more information.

Installation Location - Before installing the switch, plan its location and orientation relative to other devices and equipment:

In the front of the switch, leave at least 7.6 cm (3 inches) of space for the twisted-pair and fiber-optic cabling.

In the back of the switch, leave at least 3.8 cm (1 1/2 inches) of space for the power cord.

On the sides of the switch, leave at least 7.6 cm (3 inches) for cooling, except if the switch is installed in an open EIA/TIA rack.

2.Install or Remove a yl Module (Optional)

N o t e

Hot swapping modules is not supported. If a module is installed or removed

 

with the switch powered on, a reset will occur. Only insert or remove a module

 

during scheduled downtime with the switch powered off.

 

The HP ProCurve 3500-24, 3500-48, 3500-24-PoE and 3500-48-PoE

 

switches do not support a rear interface module.

 

1.

Remove the cover plate.

 

 

2.

Insert the module aligning with the guides in the slot. See “Installing a yl

 

 

module” on page 2-6.

 

3.

Once the contacts have engaged, use the extractor handles to seat the

 

 

module completely.

Switch the Installing

2-5