Specifications

Specifications

Environmental

 

Operating

Non-Operating

 

 

 

Temperature:

0°C to 55°C (32°F to 131°F)1

-40°C to 70°C (-40°F to 158°F)

Relative humidity:

15% to 95% at 40°C (104°F)

15% to 90% at 65°C (149°F)

(non-condensing)

 

 

 

 

 

Maximum altitude:

4.6 km (15,000 ft)

4.6 km (15,000 ft)

 

 

 

1If you are installing either the 3500yl or 6200yl switch using any of the X2 transceivers, the operating ambient temperature should not exceed 40°C (104°F).

Acoustic

Product

Accoustics

 

 

3500yl-24G-PWR

44.8 dB

 

 

3500yl-48G-PWR

45.3 dB

 

 

3500-24

42.6 dB

 

 

3500-48

43.6 dB

 

 

3500-24-PoE

44.8 dB

 

 

3500-48-PoE

45.3 dB

 

 

6200yl-24G

44.8 dB

 

 

Safety

Complies with:

EN60950

CSA 22.2 No. 60950

UL 60950

IEC 60950

A-2