Introducing the Switch

Front of the Switch

 

 

Switch LEDs

State

Meaning

Switch

 

 

 

 

 

RPS Status

On

Normal operation. RPS is connected and operating correctly. RPS could be powering

 

 

(green)

 

the unit - see table below.

the

 

 

Blinking

RPS is connected but has experienced a fault.

 

 

 

 

Introducing

 

 

Off

RPS is not connected or is not powered.

 

 

 

 

 

 

 

 

 

 

Fan Status

On

Normal operation, all fans are ok.

 

 

(green)

Blinking*

One of the unit’s fans has failed. The switch Fault LED will be blinking simultaneously.

 

 

 

 

 

 

 

 

 

 

Test

Off

The normal operational state; the switch is not undergoing self test.

 

 

(green)

On

The switch self test and initialization are in progress after the switch has been power

 

 

 

 

 

 

 

cycled or reset. The switch is not operational until this LED goes off. The Self Test LED

 

 

 

 

also comes on briefly when you “hot swap” a mini-GBIC into the switch; the mini-GBIC

 

 

 

 

is self tested when it is hot swapped.

 

 

 

Blinking*

A component of the switch has failed its self test and the switch Fault LED will blink

 

 

 

 

simultaneously.

 

 

 

 

 

 

 

Auxiliary

On

Port is in use

 

 

(green)

Off

Port is not in use

 

 

 

 

 

 

 

 

 

 

* The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.

 

 

 

 

 

Table 1-2. RPS LED Behavior

RPS modes

This table describes the behavior of the RPS LED associated with 600 RPS/EPS operation. (Power, RPS/

 

EPS, Fault)

 

 

 

 

 

 

Power LED

RPS LED

Fault LED

Description

 

 

 

 

On

Off

Off

Normal operation. 600 RPS/EPS is not connected or not powered.

 

 

 

 

On

On

Off

Normal operation. 600 RPS/EPS is available.

 

 

 

 

On

On/Off

Blinking

Unit has experienced a fault and another LED will be blinking to

 

 

 

determine fault.

 

 

 

 

Off

On

Blinking

600 RPS/EPS is running the switch in failover mode. No AC power to the

 

 

 

unit, or the internal power supply has failed.

 

 

 

 

Off

Off

Off

Unit is un-powered by AC input line and the external 600 RPS/EPS

 

 

 

 

On

Blinking

Blinking

The 600 RPS/EPS unit has experienced a fault.

 

 

 

 

On

Blinking

Off

The 600 RPS/EPS unit is unavailable to power the Switch in event of an

 

 

 

internal power supply failure. The 600 RPS/EPS is designed to provide

 

 

 

power to one of its connected switch devices at a time. The Power

 

 

 

Status LED on the 600 RPS/EPS unit will also be blinking for this device.

 

 

 

 

1-6