W A R N I N G
E q u i p m e n t C a b i n e t
N o t e
Installing the Switch
Installation Procedures
When the self test completes successfully:•The Power and Fan Status LEDs remain on.
•The Fault and Test LEDs go off.
•The port LEDs (includes the expansion module LEDs) go into their normal operational mode:
–If the ports are connected to active network devices, the LEDs behave according to their function, Link or Activity.
–If the ports are not connected to active network devices, the LEDs will stay off.
If the LED display is different than what is described above, especially if the Fault and Test LEDs stay on for more than 60 seconds or they start blinking, the self test has not completed correctly. Refer to chapter 4, “Troubleshooting” for diagnostic help.
3.After the self test has completed successfully disconnect the power cord in preparation for mounting the switch.
5. Mount the Switch
After the switch passes self test, you are ready to mount the switch in a stable location. The Series 6400cl Switch devices can be mounted in these ways:
■in a rack or cabinet
■on a horizontal surface
Rack or Cabinet Mounting
The Series 6400cl Switch devices are designed to be mounted in any EIA- standard
For safe operation, please read the installation precautions on page
The
Complete step 1, and plan which four holes you will be using in the cabinet and install all four clips. Then proceed to step 2.
Switch the Installing