Installing the Switch
Installing the Switch
Installation Procedures
| 3. (Optional) Install or Remove a Transceiver |
|
|
W A R N I N G | The ProCurve X2 fiber optic transceivers are Class 1 or Class 1M laser |
| devices. Avoid direct eye exposure to the beam coming from the |
| transmit port. |
| a. Slide the transceiver in until it stops.1 |
|
1If you are installing either of the Series 6400cl Switch devices using a fiber transceiver, the operating ambient temperature should not exceed 40°C (104°F). See transceiver specifications in the ProCurve Switch cl Modules Installation Guide.
b.Push firmly until the gasket seats against the bulkhead.
Bail
N o t e | When switch power is on, the Link and Activity LEDs will come on for |
| approximately two seconds and then go off. This is confirmation the |
| transceiver is installed and seated correctly. |
| c. If your transceiver has a bail, move the bail up, if not your transceiver is |
| |
| now completely installed. Refer to the ProCurve Switch cl Module |
| Installation Guide for more details. |
To remove the transceiver:
If your transceiver has a bail, lower the bail until it is approximately horizontal, and then using the bail, pull the transceiver from the slot. If your transceiver does not have a bail, pull the transceiver straight out.