Module Tape DDS
DDS Tape Module
DDS Tape Module Front Panel
Status Lights
Table 3 lists the status light indications and actions for the tape light and clean light.
Tape Light
The tape light monitors the following tape parameters:
∙tape loading or unloading
∙tape loaded or unloaded
∙
∙read/write activity
Clean Light
The DDS tape module monitors the number of errors occurring during read and write operations. If the number of errors exceeds the error limit, the clean light flashes amber. This condition can be caused by a hard read or write error, dirty tape heads, or the tape nearing the end of its useful life.
If the clean light flashes amber:
1.Clean the tape heads.
2.Repeat the last operation and see if the clean light flashes again.
3.If the clean light flashes again, copy the data from the old tape onto a new tape then discard the old tape. The clean light is cleared after you load a cleaning cartridge, or when the DDS tape module is power cycled.
4.If the clean light flashes after cleaning the tape heads, you should service the DDS tape module.
Table 3. DDS Tape Module Status Light Indications
Tape Light | Clean Light | Indication/Recommended Action |
|
|
|
Off | Off | No power or passed |
|
|
|
Flashing Green | Off | Tape loading or unloading, or |
(1 flash/second) |
|
|
|
|
|
Flashing Green | Off | Tape loaded and read/write activity. |
(2 flashes/second) |
|
|
|
|
|
Green | Off | Tape loaded. Ready. |
|
|
|
Amber or Green | Flashing Amber | Tape heads are dirty. Copy the data to a new tape, |
| (1 flash/second) | discard the old tape, and clean the tape heads. |
|
|
|
Amber or Green | Amber | Drive fault. Replace the DDS tape module. |
|
|
|