Module Tape DDS

DDS Tape Module

DDS Tape Module Front Panel

Status Lights

Table 3 lists the status light indications and actions for the tape light and clean light.

Tape Light

The tape light monitors the following tape parameters:

tape loading or unloading

tape loaded or unloaded

self-test in progress

read/write activity

Clean Light

The DDS tape module monitors the number of errors occurring during read and write operations. If the number of errors exceeds the error limit, the clean light flashes amber. This condition can be caused by a hard read or write error, dirty tape heads, or the tape nearing the end of its useful life.

If the clean light flashes amber:

1.Clean the tape heads.

2.Repeat the last operation and see if the clean light flashes again.

3.If the clean light flashes again, copy the data from the old tape onto a new tape then discard the old tape. The clean light is cleared after you load a cleaning cartridge, or when the DDS tape module is power cycled.

4.If the clean light flashes after cleaning the tape heads, you should service the DDS tape module.

Table 3. DDS Tape Module Status Light Indications

Tape Light

Clean Light

Indication/Recommended Action

 

 

 

Off

Off

No power or passed self-test.

 

 

 

Flashing Green

Off

Tape loading or unloading, or self-test in progress.

(1 flash/second)

 

 

 

 

 

Flashing Green

Off

Tape loaded and read/write activity.

(2 flashes/second)

 

 

 

 

 

Green

Off

Tape loaded. Ready.

 

 

 

Amber or Green

Flashing Amber

Tape heads are dirty. Copy the data to a new tape,

 

(1 flash/second)

discard the old tape, and clean the tape heads.

 

 

 

Amber or Green

Amber

Drive fault. Replace the DDS tape module.

 

 

 

30