Troubleshooting & Diagnostics
Module Status Lights
Table 6. Fan Module Status Light IndicationsStatus Light | Indication | Recommended Action |
|
|
|
Off | No power or fan not operating. |
|
|
|
|
Green | Normal operation. | None required. |
|
|
|
Amber | Fan failure. Fan speed is too slow or the | Replace the fan module. |
| fan has stopped blowing air. |
|
|
|
|
Status Light | Indication | Recommended Action |
|
|
|
Off | No power or power module not | Check to see if power cords are plugged |
| operating. | in. Check to see if storage system power |
|
| switch is turned on. |
|
|
|
Green | Normal operation. | None required. |
|
|
|
Amber | Both fans are missing or failed, over- | See “Power Module Troubleshooting |
| current condition, or power supply | Procedures” in this chapter. |
| failure. |
|
|
|
|
Status Light | Indication | Recommended Action |
|
| |
|
|
|
|
|
|
| Off | No power, disk module failed, or self- | Check storage system power. If power |
|
|
|
| test passed. | is present and |
|
|
|
|
| is required. If the disk module failed, |
|
|
|
|
| replace the disk module. |
|
|
|
|
|
|
| |
Flashing Green | Disk module is reading or writing data. | None required. |
|
| |
|
| Normal operation. |
|
|
|
|
|
|
|
|
|
| Green | Drive fault1 or | If there is a drive fault, replace the disk |
|
|
|
|
| module. If |
|
|
|
|
| is required. |
|
|
|
|
|
|
| |
|
|
|
|
| |
Notes: |
|
|
|
| |
1. | A solid green status light at any time other than during a |
| Troubleshooting | ||
| Replace the disk module. |
|
| ||
|
|
|
| ||
2. | Termination problems can prevent successful completion of a |
|
| ||
| termination problems on the SCSI bus. See “SCSI Bus Troubleshooting Procedures”. |
|
| ||
|
|
|
| 43 |
|
|
|
|
|
| |
|
|
|
|
|
|