DDS Tape Module
Unloading a DDS Tape Cartridge
Module Tape DDS
Unloading a DDS Tape Cartridge
To unload a DDS tape cartridge:
Press the cartridge unload button. This starts the unload sequence which winds the tape to the beginning, unthreads the tape, and ejects the cartridge. The unload sequence takes about 25 seconds for a write- enabled DDS tape cartridge and 10 seconds for a
Forcing DDS Tape Cartridge Ejection
CAUTION! You may lose data if you force the ejection of a DDS tape cartridge. Also, the tape may not be formatted during a forced ejection because the
If you press the cartridge unload button when the DDS tape module is busy, it may take some time to respond because it will finish the operation it is performing first. This ensures that the operation is terminated in a controlled manner and no data is lost. However, you may need to unload a DDS tape cartridge immediately, even if you risk losing data.
To force DDS tape cartridge ejection, perform one of the following:
∙Press the cartridge unload button three times within a
∙Hold the cartridge unload button down for at least five seconds.
Following either of these actions, a
32