Install the 4Gb SAN Switch

CAUTION:

For switch revision levels 0A and 0B only (running Fabric OS versions earlier than 5.2.1b) — DHCP is not supported on these models. Do not install multiple switches at the same time with default addresses, as address conflicts will occur. Locate switch revision levels on the switch or shipping carton. See Set the IP address.

For switch revision levels 0C and above only (Fabric OS 5.2.1b or later) — DHCP is supported and enabled by default for switches running Fabric OS 5.2.1b (switch rev 0C) or later. In this case, IP address conflicts will not occur during multiple switch installations. Locate switch revision levels on the switch or shipping carton. See Using External DHCP.

The Brocade 4Gb SAN switch is a hot-pluggable device. The enclosure power may be on or off when inserting the switch. Follow these steps to install the 4Gb SAN Switch.

1.Locate the appropriate interconnect bay in the rear of the enclosure per the appropriate HP BladeSystem Enclosure Setup and Installation Guide provided with your enclosure.

Remove the slot cover (if installed).

IMPORTANT:

Populate all enclosure I/O bays with the appropriate component (for example a switch, Pass-Thru or one of the blank panels provided with the enclosure).

CAUTION:

Properly ground yourself before handling the switch.

2.Press the handle latch to release the installation handle. See Figure 4.

24Setup

Page 24
Image 24
HP Brocade 4Gb SAN c-Class BladeSystem manual Install the 4Gb SAN Switch