HP Brocade 4Gb SAN c-Class BladeSystem manual Disabling and enabling a switch

Models: Brocade 4Gb SAN c-Class BladeSystem

1 88
Download 88 pages 3.97 Kb
Page 36
Image 36

Disabling and enabling a switch

By default, the switch is enabled after power on and diagnostics and switch initialization routines complete. You can disable and re-enable the switch as necessary.

To disable:

1.If you have not already done so, connect to the switch and log in as admin as described in Connect to the Command Line Interface.

2.Issue the switchDisable command.

All Fibre Channel ports on the switch are taken offline. If the switch was part of a fabric, the fabric reconfigures.

To enable:

1.If you have not already done so, connect to the switch and log in as admin as described in Connect to the Command Line Interface.

2.Issue the switchEnable command.

All Fibre Channel ports that pass the Power-on Self Test (POST) are enabled. If the switch has interswitch links (ISLs) to a fabric, it joins the fabric.

Disabling and enabling a port

To enable a port:

1.Connect to the switch and log in as admin as described in Connect to the Command Line Interface.

2.Issue portenable portnumber where portnumber is the port number of the port you want to enable.

To disable:

1.If you have not already done so, connect to the switch and log in as admin as described in Connect to the Command Line Interface.

2.Issue portdisable portnumber where portnumber is the port number of the port you want to disable.

36Setup

Page 36
Image 36
HP Brocade 4Gb SAN c-Class BladeSystem manual Disabling and enabling a switch, Disabling and enabling a port