Table 9 Connecting via a management station

 

Management

First switch

Second switch

Third switch

 

station

 

 

 

 

 

 

 

 

Ethernet

192.168.1.09

192.168.1.10

204.1.1.11

204.1.1.12

 

 

 

 

 

FCIP

192.168.65.09

192.168.65.10

192.168.65.11

192.168.65.12

 

 

 

 

 

Gateway

192.168.1.10

any, not self

192.168.1.10

192.168.1.10

 

 

 

 

 

Maintaining the 4Gb SAN Switch

The 4Gb SAN Switch does not require any regular physical maintenance.

However, it is critical that environmental conditions, described in Environmental requirements are met to help prevent switch failure due to heat stress or improper air flow.

Installing dust covers in empty ports

The dust covers included in the 4GB SAN Switch shipping carton, (see Figure 1) must be inserted in ports where SFPs are not installed. Installing dust covers ensures proper airflow and helps reduce dust contamination of the switch.

Replacing an SFP transceiver

In some cases you might need to reinstall an SFP transceiver.

To remove an SFP transceiver:

1.Press and hold the cable release.

2.Remove the cable from the transceiver.

3.Pull the bail (wire handle) to release the transceiver.

4.Grasp the bail, and gently but firmly pull the transceiver out of the port.

5.Repeat this procedure for the remaining ports as required.

Brocade 4Gb SAN Switch for HP c-Class BladeSystem

43

Page 43
Image 43
HP Brocade 4Gb SAN c-Class BladeSystem manual Maintaining the 4Gb SAN Switch, Installing dust covers in empty ports