Environmental requirements

To ensure proper operation, the switch must not be subjected to environmental conditions beyond those for which it was tested. The ranges specified in Table 17 list the acceptable environment for both operating and non-operating conditions.

Table 17 Environmental requirements

Condition

Acceptable range during operation

Acceptable range during

 

 

non-operation

 

 

 

Ambient

104°F/40 °C at sea level, derated 1 C

-40°C to 70°C with maximum rate of

temperature

per 1000 ft above sea level

change of 20 C /hr

Humidity

5% to 90% relative humidity,

50% to 80% relative humidity,

 

non-condensing

non-condensing

 

 

 

Altitude

0 to 10,000 ft (3 km) above sea level

0 to 40,000 ft (12 km) above sea level

 

 

 

Shock

40 G, 2mS duration

140 G, 2mS,

 

 

 

Vibration

0.5 G, 10–500 Hz

2.0 G, 5–500 Hz

 

 

 

Airflow

47 cubic ft/minute

None required

 

 

 

Supported SFPs

Do not use unsupported SFPs; they can affect switch operability. They may not fit correctly and may void your warranty. See Optional hardware kits for a list of supported SFPs.

For a complete list of supported devices, refer to the latest version of the HP StorageWorks SAN design reference guide: http://h18000.www1.hp.com/products/ storageworks/san/documentation.html.

Supported HBAs

For a list of HBAs that have been tested and are known to work with the SAN switches, refer to the latest version of the HP StorageWorks SAN design reference guide: http://h18000.www1.hp.com/products/storageworks/san/documentation.html.

76

SAN Switch technical specifications

Page 76
Image 76
HP Brocade 4Gb SAN c-Class BladeSystem manual Environmental requirements, Supported SFPs, Supported HBAs