C
POST Error Messages
An error message results if the
Not all computers use all of the codes listed.
Recommended Actions are to be taken in incremental steps. Perform one step at a time and continue only if the action does not cure the problem.
POST Error Messages
Screen Message | Probable Cause | Recommended Action |
|
|
|
Gate 20 Error | BIOS cannot access | Reseat memory modules. |
| memory over 1MB. | Replace memory modules. |
|
|
|
Parity Error | Fatal memory parity | Reseat memory modules. |
| error. System halts after | Replace memory modules. |
| displaying this message. |
|
Boot Failure... | BIOS could not boot from |
| the device. This message |
| is usually followed by |
| information about the |
| specific device. |
Reseat the device data and power cables.
Replace the device data cable. Replace the device.
Replace the system board.
Invalid Boot Diskette | Diskette in drive A: not | Replace the diskette. |
| bootable. |
|
|
|
|
Drive Not Ready | BIOS could not configure | Reseat the device data and power |
| drive A: during POST. | cables. |
|
| Replace the device data cable. |
|
| Replace the device. |
|
| Replace the system board. |
|
|
|
Drive A: Error | BIOS could not configure | Reseat the device data and power |
| drive A: during POST. | cables. |
|
| Replace the device data cable. |
|
| Replace the device. |
|
| Replace the system board. |
|
|
|
Insert BOOT Diskette In | BIOS could not find a | Replace the diskette. |
A: | bootable diskette in drive |
|
| A:. |
|
|
|
|
| Service Reference Guide, dx2000 uT |