Chapter 6. Administration of the Telecommuting Module

Save configuration saves your preliminary configuration to the permanent configuration and puts it into use.

Continue testing shows a new page with only the other two buttons.

Revert cancels this test of the preliminary configuration without saving.

If you do not press any button within the time limit, the Telecommuting Module will revert to the old permanent configuration, just as if you had pressed Revert. This is useful if you happen to configure your Telecommuting Module so it isn’t accessible from your browser.

After the timeout, pressing either of the three buttons will show a new page which will inform you that the test run was aborted.

Restarting the Telecommuting Module by cycling the power also cancels the test.

Show Message About Unapplied Changes

When there are settings which are not yet applied, a warning about this will be shown on the web pages. Select here where this message should be shown. The options are On every page, On the Save/Load Configuration page (this page) and Never.

Backup

All configurations can be saved to and loaded from diskette or file. This does not affect the permanent configuration.

Save to diskette

Insert a formatted diskette into the Telecommuting Module’s floppy drive and press Save to diskette to save the preliminary configuration. Do not remove the diskette until the light on the floppy drive goes out.

Check that you get a confirmation of the saving. If not, the diskette may be faulty.

53

Page 61
Image 61
HP VCX Software manual Show Message About Unapplied Changes, Backup, Save to diskette