6 Tests and Error Messages
Error Message Summary
Code # | Cause / Symptom | Short message (US) |
|
|
|
0522h | HDD # 2 not detected (but configured in CMOS) | IDE Device # 2 Error |
|
|
|
0523h | HDD # 3 not detected (but configured in CMOS) | IDE Device # 3 Error |
|
|
|
0530h | Found a drive on slave connector only (primary) | IDE Device Error |
|
|
|
0531h | Found a drive on slave connector only (secondary) | IDE Device Error |
|
|
|
0600h | Found less video memory than configured in CMOS | Video Memory Error |
|
|
|
0700h | Found less DRAM memory than at previous boot | System Memory Error |
|
|
|
0711h | Defective SIMM (module 1, bank 1) | System Memory Error |
|
|
|
0800h | Found lower cache size than configured | System Cache Error |
|
|
|
0801h | Cache | System Cache Error |
|
|
|
0A00h | Plug and Play video | DDC Video Error |
|
|
|
The following table summarizes the most significant of the problems that can be reported.
Message | Explanation or Suggestions for Corrective Action |
|
|
Operating system not found | Check whether the disk, HDD, FDD or |
| connected. |
| If it is connected, check that it is detected by POST. |
| Check that your boot device is enabled on the Setup Security |
| menu. |
| If the problem persists, check that the boot device contains the |
| operating system. |
|
|
Missing operating system | If you have configured HDD user parameters, check that they are |
| correct. Otherwise, use HDD type “Auto” parameters. |
|
|
Resource Allocation Conflict | Clear CMOS. |
0079 on system board |
|
|
|
Video Plug and Play interrupted or | You may have powered your computer Off/On too quickly and the |
failed. | computer turned off Video plug and play as a protection. |
|
|
System CMOS checksum bad - run | CMOS contents have changed between 2 |
Setup | Setup for configuration. |
|
|
No message, system “hangs” | Check that the main memory modules are correctly set in their |
| sockets. |
|
|
115