Restoring from service position

Maintenance

7Grip the front edge of the unit and pull forwards until it stops.

8Lift the unit until it stops and a clicking sound is heard.

9The unit locks automatically in the vertical position.

Restoring from service position

1Grip the front edge of the unit and loosen the lock, fold down and slide in the unit.

2Replace the cutting height stay and the belt. Tension the belt with the belt adjuster.

3Fit the front cover.

4Set the cutting height control to one of the positions 1-7

Checking the blades

To achieve the best mowing results it is important that the blades are undamaged and well-sharpened.

Check that the blades’ attachment screws are tight.

IMPORTANT INFORMATION

Replacing or sharpening the blades should be conducted by an authorised service workshop.

The blades should be balanced after sharpening.

Damaged blades should be replaced when hitting obstacles that result in a breakdown. Let the servicing dealer judge whether the blade can be repaired/ground or must be discarded.

WARNING! If the blades are cracked,

!whether caused by poor repair or other damage, they could break while being used. The risk increases if the blades are poorly balanced.

Removing the BioClip plug

To change a Combi unit from BioClip function to cutting unit with rear ejection, remove the BioClip plug located under the unit with three screws.

1Put the unit in the service position, see Service position for the cutting unit.

2Loosen the knob holding the BioClip-plug and remove the plug.

3Replace the unit in normal position. Fit the BioClip plug in the reverse order.

30 – English